Uniqcli Security
Altronix

Altronix FireSwitch108 Managed NAC Power Extender

Part number FIRESWITCH108

Altronix FireSwitch108 Managed NAC Power Extender

NDAA Section 889 / TAA-compliant — country of origin confirmed on quote
$606.16$1,175.94Save 48%
Factory-direct — ships in ~2 weeks
Or request a TAA-compliant quote →
Free US delivery 30-day returns NDAA 889 / TAA compliance verified on every order

We confirm stock, country of origin and compliance before any order — no payment up front.

Highlights

  • Cost-effective managed NAC Power Extender.
  • Interfaces with 12 or 24VDC Fire Alarm Control Panels (FACP).
  • Provides auxiliary power to support system accessories.
  • Electronically regulated and filtered 24VDC power.
  • UL and cUL listed.

Sold by Uniqcli, an independent technology reseller and systems integrator. This is an Uniqcli-operated storefront, not Altronix's official website. Altronix marks belong to their owner. Manufacturer warranty and license terms apply. See the Terms of Use & Sale and Return & RMA Policy.

Tech specs

Specifications
Product TypeAlarm Control Panel Expansion Module
Environmentally FriendlyYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Country of OriginUnited States
Height15.5" mm
Width12.3" mm
Depth4.5" mm
Certifications & StandardsUL CAN/ULC-S527-99 Control units for Fire Alarm Systems CSFM NFPA 72 Compliant
Product ModelFIRESWITCH108
Device SupportedControl Panel
Input Voltage24 V DC V DC
Packaged Quantity1
Limited WarrantyLifetime
Additional InformationInput : Power input: 120VAC 60Hz, 4.8 amp. Two (2) Class A or two (2) Class B FACP inputs. Two (2) configurable inputs trigger via Class A or Class B FACP signal circuits(polarity reversal) or dry contacts. Output : 24VDC voltage regulated power-limited NAC outputs. Output power: 10 amp max. total alarm current. 7 amp max.stand-by without battery back-up. 1 amp with battery back-up including dedicated Aux. output. For Canadian applications Stand-by with battery backup is limited to 0.45 amp. 2.5 amp max current per output. One (1) auxiliary output rated at 1 amp (regulated, battery backed up). 0.45 amp for Canadian applications. Any NAC can be configured as an Aux. output with or without battery back-up (special application only). When set as Aux. output, the output is not supervised. Programmable supervised indicating circuit outputs: Eight (8) Class B or Four (4) Class A, or any combination of Class A and Class B circuits. Thermal and short circuit protection with auto reset. Battery Backup: Built-in charger for sealed lead acid or gel type batteries. Automatic switchover to stand-by battery when AC fails. Zero voltage drop when switching over to battery backup. Supervision : AC fail supervision (form "C" contacts). Battery fail & presence supervision (form "C" contacts). Low power shutdown. Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Special Features: Programmable LCD display interface. EOL resistor value is programmable by output. Ethernet port interface for remote programmability and monitoring. 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. Sync protocols include Potter, Gentex®, System Sensor® , and CooperWheelock®. Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit). Compatible with 12VDC or 24VDC fire panels. Output loop supervision directed to input 1 or input 2. Common trouble Dry N.C. output for reporting trouble to remote FACP. Ground fault detection - Ground fault maximum test impedance 1,000 ohm. Ground fault Dry N.O. output to report ground fault to remote FACP. CO Temporal Code 4 (NFPA720) include Gentex® , Potter and System Sensor® devices. Electrical: Operating temperature: 0° C to 49° C ambient. BTU/Hr.: 122.84BTU/Hr. System AC input VA requirement: 576VA. Visual Indicators: LCD display - Indicates troubles and conditions of operation. Trouble Condition Memory facilitates quick identification of an intermittent/fault (short circuit, open or ground) which has previously occurred on one or more signaling circuit outputs. LCD displays which output the fault has occurred on.
Weight (Approximate)12.39 lb g

Related intrusion & alarm

Request a TAA-compliant quote for Altronix FireSwitch108 Managed NAC Power Extender - For Control Panel